Mini CVD Tube Furnace OTF-1200X-S50-2F |
||
Furnace Structure |
Heavy duty steel casing |
|
Power Consumption |
1.75KW |
|
Temperature |
1200 Max. for < 1hr |
|
Processing Tube |
Quartz tube 50 x 43 x 450mm (O.D x I.D x Length) |
|
Heating Zone |
Total heating zone length: 8" (200mm); Constant temp. zone: 2.3" (60mm) (+/-1°C) @ 900 °C. |
|
Temperature Controller |
|
|
Heating Elements |
Fe-Cr-Al Alloy doped by Mo |
|
Digital Vacuum Gauge |
|
|
Two Channel Gas Mixing Station |
|
|
Vacuum Flanges and Fittings |
|
|
Vacuum Pump |
|
OTF-1200X-80-I-F3LV-UL |
|
Furnace Construction |
|
Power Consumption |
2.5 KW |
Input Voltage |
AC 208-240V Single Phase, 50 or 60 Hz |
Maximum Temperature |
1200 °C |
Continuous workingTemperature |
1100 °C |
Maximum Heating Rate |
<= 20 oC /min |
Heating Zone Length |
400 mm |
Constant Temperature Zone |
150mm (+/-1°C) |
Temperature Accuracy |
+/- 1°C |
Heating Elements |
Fe-Cr-Al Alloy doped by Mo |
Temperature Controllers |
|
Tube Size and Materials |
Quartz tube: OD: 80mm x ID: 75 mm x Length: 1000 mm |
Digital Vacuum Gauge |
|
Vacuum Sealing Flanges |
Two stainless steel flanges with both vacuum gauge and valve. The leaking rate of the flange is 6 mtorr/min in max. and 2 mtorr/min in stable conditions. Note: For the 24 hours curve display the time segment through 08:00:00~21:10:00 in X-axis is skipped over in the chart; therefore, a steep variance is present. |
Oxygen Monitoring |
An Oxygen Sensor can be used to monitor the oxygen level of gas(es) used in CVD systems for preventing or reducing oxidation. |
Vacuum Pump |
|
Gas Flow Meter and Pressure Meter |
1) Compact direct read flow meter, 10-100 cc/min.
|
Valves |
Four stainless steel valves are installed in the side panel of mobile cart to control mixing of three inlet gases separately. |
1700 ⁰C CVD Furnace System GSL-1700X-F3LV |
||
Tube Furnace |
Structure |
|
Power Consumption |
5kW Max. |
|
Input Voltage |
AC 208~240V, Single Phase, 50/60Hz |
|
Max. Heating Temp. |
1700°C |
|
Max. Heating Rate |
5°C/min |
|
Max. Cooling Rate |
5°C/min |
|
Heating Zone Length |
455mm (18") |
|
Constant Temp. Zone |
150(+/-1C) |
|
Temperature Accuracy |
+/-1°C |
|
Temperature Controller |
|
|
Heating Elements |
1800 grade MoSi2 ( 8 pcs ) |
|
Tube Materials and Size |
|
|
Digital Vacuum Gauge |
|
|
Vacuum Sealing |
|
|
Vacuum Pump and fittings |
Vacuum Pump |
|
Fittings |
The standard vacuum fittings include:
|
|
Gas Flow Meter |
|
|
Oxygen Monitoring |
An Oxygen Sensor can be used to monitor the oxygen level of gas(es) used in CVD systems for preventing or reducing oxidation. Please click the picture below to learn more: |
|
Shipping Info |
Product Dimensions |
|
New weight |
450 lb (in total) |
|
Shipping Dimensions |
Two cases in one pallet: 45 x 45 x 35"/ea. case |
|
Shipping Weight |
500 lb (in total) |
|
Warranty |
One year limited warranty (Consumable parts such as processing tubes, o-rings and heating elements |
|
Compliance |
|